The Challenge
The strength of porous aluminum oxide beads is highly dependent on maintaining specific moisture conditions during curing. For decades, the facility relied on intermittent oven weight-loss testing to determine product moisture.
Long process residence times and infrequent sampling made it difficult to identify and correct moisture-related issues before significant quantities of material were affected.
Delayed Laboratory Results = Hours could pass before moisture problems were identified.
Infrequent Testing = Moisture measurements were performed only once per shift.
Sampling Variability = Individual samples could miss or misrepresent actual process conditions.
Off-Specification Material = Insufficient moisture could result in entire tons of material falling outside specification.
Limited Process Adjustments = Adjustments were previously restricted by the availability of moisture data.
The Solution
IR-3000 Sensor
MoistTech supplied a pre-calibrated IR3000 near-infrared moisture sensor specifically configured for the customer’s porous aluminum oxide bead application.
Installed at the discharge chute following the curing drum, the sensor provides continuous, non-contact moisture measurements to the facility’s distributed control system (DCS), allowing real-time process adjustments.
Installation Specifications
Sensor: IR3000
Moisture range: 25–35%
Process temperature: 180°F
Control system: DCS
Installation: After curing drum
Accessory: Air purge
The Results
Improved Moisture Control: Maintains moisture within the required operating range.
Faster Process Response: Identifies moisture-related process upsets sooner.
Exceptional Accuracy: Measurement accuracy exceeded the customer’s application requirements.
Simplified Operations: Replaces tedious testing tasks and enables real-time adjustments.