Foundry Sand Moisture

A metal casting foundry needed a more reliable method of measuring moisture in its reclaimed sand system. After sand molds were broken away from poured castings, the recovered sand was returned to the production process for conditioning and reuse.

The facility previously relied on conductivity probes that required direct contact with the sand. Variations in material depth made consistent contact difficult, while excessive sand buildup on the probes affected measurement reliability.


Without dependable moisture measurements, maintaining consistent sand conditions became challenging. The customer estimated that poor sand quality contributed to at least 2% monthly material waste, creating opportunities to improve process control and reduce scrap.

IR3000 Sensor

MoistTech supplied two IR-3000 near-infrared moisture sensors to provide continuous, non-contact moisture measurement throughout the foundry’s sand reclamation process.

One sensor was installed over the return sand conveyor, with a second positioned over the muller feeder belt. These locations provide moisture measurements at critical stages before the sand is conditioned and returned to production.

Unlike the existing conductivity probes, the IR-3000 measures moisture without physically contacting the material, eliminating the need for consistent probe contact and avoiding measurement interference caused by material buildup on the sensing surface.

The real-time moisture information provides operators with additional visibility into changing sand conditions and can support more informed adjustments to water addition and sand conditioning.

Improved Moisture Measurement Reliability: Non-contact measurement eliminates the challenges associated with fluctuating sand levels and material buildup on conventional contact probes.

Greater Process Visibility: Continuous moisture readings at two locations provide additional information about reclaimed sand conditions throughout the return system.

Improved Sand Quality Control: More dependable moisture data supports consistent sand conditioning and helps operators identify variations that may contribute to casting defects and material waste..

Reduced Scrap Potential: The customer identified poor sand quality as a contributor to an estimated 2% monthly material waste. Improved moisture control creates an opportunity to address moisture-related quality issues.

Defined Performance Targets: The facility established operating goals of at least 75% overall daily operation, no more than 5% daily scrap, and a minimum 15% return on investment with a targeted four-month payback period.

Project Details

Industry

Mining & Minerals

Application/Product

Reclaimed Sand

Location

Minnesota, United States

Case Study Infographic

Click to enlarge ↗

Production Process Flow

CASTING

RECLAIM

MoistTech IR3000

MOISTURE MEASUREMENT

MoistTech IR3000

CONDITION

REUSE

Installation Photos

The facility's previous contact-based measurement system was affected by changing sand levels and buildup on the probes. Installing two non-contact IR-3000 sensors provides continuous moisture visibility at key points in the sand reclamation process, supporting more reliable monitoring and better-informed conditioning decisions.

— Project Overview – Foundry Sand Reclamation
IR-3000: Reliable Moisture Measurement for Foundry Sand
MoistTech IR-3000 non-contact NIR moisture sensor
  • Continuous, Non-Contact Moisture Measurement
  • Eliminates Contact Probe Buildup Issues
  • Accommodates Variations in Sand Levels
  • Real-Time Moisture Data for Sand Conditioning
  • Supports Consistent Reclaimed Sand Quality
  • Integrates with Industrial Control Systems

Improve Moisture Control in Your Foundry Sand Process

Discover how MoistTech's IR-3000 online moisture sensor provides continuous, non-contact measurement of reclaimed foundry sand to support consistent material quality, improved process control, and reduced moisture-related waste.

Talk to a MoistTech Specialist