OVERVIEW
A specialty ceramic materials manufacturer in Ohio sought a faster method of evaluating residual moisture in zirconia clinker following high-temperature furnace processing and quenching. Traditional oven weight loss testing was too slow to support timely process control decisions, creating a need for a more responsive moisture measurement solution.
The Challenge
Measuring residual moisture in zirconia clinker presents unique challenges due to the relatively large granule size and uneven distribution of moisture throughout the material.
The manufacturer’s existing oven weight loss method did not provide results quickly enough for optimal process control.
- Slow conventional moisture testing
- Non-uniform moisture distribution
- Large clinker granules
- Delayed process control decisions
- Difficulty rapidly classifying material by moisture level
The Solution
IR3000 Sensor
The manufacturer installed a MoistTech IR3000 NIR moisture sensor adjacent to the furnace drag chain, which transfers clinker from the quench tank.
Operators collect clinker samples and position them beneath the sensor for non-contact analysis. Due to the unique characteristics of the material, the manufacturer developed a proprietary data processing algorithm that analyzes changes in the IR3000 output to extract useful moisture level information.
This approach provides operators with a moisture level indication within two minutes, supporting faster material classification and rotary kiln control.
The Results
The implementation of MoistTech technology provided the manufacturer with a rapid method of evaluating clinker moisture levels, improving process consistency and supporting more informed operational decisions.
Rapid moisture information supports material segregation, improved process consistency and more informed rotary kiln control.